A pool heat pump is sized by the heat it must add to the water, and the calculator starts from the pool’s surface area because that is where most heat is lost. This swimming pool heat pump sizing calculator multiplies the surface area by your desired temperature rise and a BTU factor of 5 per square foot per degree Fahrenheit, then reduces the result by 30 percent if the pool is covered. It opens with a 450 ft² pool, a 15°F rise and no cover.
Swimming Pool Heat Pump Sizing Calculator
BTU/h output needed from a pool heat pump, from pool surface area and desired temperature rise (heat pumps run at a smaller BTU/ft² rate than gas heaters).
How do you size a pool heat pump?
Multiply the surface area by the temperature rise and by 5, then by 0.7 if the pool has a cover. The result is the heat output in BTU per hour that the heat pump has to add to the water, and the variables are explained under the formula.
Output (BTU/h) = Area × Temperature rise × 5 × Cover factor
Cover factor = 0.7 if covered, 1 if not
Where:
- Area = pool surface area in square feet
- Temperature rise = how many °F you want to raise the water above its natural temperature
- 5 and 0.7 = values built into the calculator
The calculator’s note says the figure of 5 BTU per square foot per °F is lower than a gas heater would use, because a heat pump runs for long periods. These are the calculator’s assumptions, so check the result with a supplier.
Worked examples
Worked example: the starting values
A 450 ft² pool, 15°F rise, no cover:
Output = 450 × 15 × 5 = 33,750 BTU/h
Worked example: with a cover
The same pool with a cover:
Output = 450 × 15 × 5 × 0.7 = 23,625 BTU/h
Worked example: a larger pool
An 800 ft² pool, 10°F rise, uncovered:
Output = 800 × 10 × 5 = 40,000 BTU/h
Temperature rise and output compared
For the 450 ft² pool:
| Rise | Uncovered | Covered |
|---|---|---|
| 10°F | 22,500 BTU/h | 15,750 BTU/h |
| 15°F | 33,750 BTU/h | 23,625 BTU/h |
| 20°F | 45,000 BTU/h | 31,500 BTU/h |
How do you find the surface area?
For a rectangular pool, multiply length by width. A 15 ft by 30 ft pool is 450 ft². For a round pool, use the area of a circle, 3.14 × radius². A pool 18 ft across has a radius of 9 ft, so its area is 3.14 × 9 × 9, about 254 ft². Irregular pools can be split into simpler shapes.
Choosing the temperature rise
The temperature rise is the difference between the water temperature you want and the temperature it would reach without heating, such as the usual water temperature in your coolest weeks. A bigger rise needs more output. Choose it from your own water and air temperatures.
What the swimming pool heat pump sizing calculator leaves out
The calculator does not use pool depth or volume, local climate, wind, sun, shade, the heating time you will allow or the pool’s use. It does not give a running cost or a purchase price either. Because heat pump performance varies with air temperature, ask the manufacturer for the rated output at your conditions.
How do you pick a heat pump from the result?
Compare the result with the rated heating output of models, and ask what air and water temperatures the rating assumes. Models are sold in set sizes, so look at the nearest size above the result. A larger heat pump heats the pool faster but costs more to buy.
Pool size and output compared
At a 15°F rise with no cover:
| Surface area | Output |
|---|---|
| 200 ft² | 15,000 BTU/h |
| 450 ft² | 33,750 BTU/h |
| 600 ft² | 45,000 BTU/h |
| 800 ft² | 60,000 BTU/h |
Worked example: a round pool
A round pool 18 ft across has an area of about 254 ft². With a 15°F rise and no cover:
Output = 254 × 15 × 5 = 19,050 BTU/h
With a cover:
Output = 254 × 15 × 5 × 0.7 = 13,335 BTU/h
What a pool cover saves in this calculator
For the 450 ft² starting pool at a 15°F rise, the cover lowers the figure from 33,750 to 23,625 BTU/h, a difference of 10,125 BTU/h. That is the 30 percent reduction built into the calculator. A lower required output can mean a smaller heat pump, so the cover choice is worth deciding before you shop.
Converting the output to kW
Divide BTU per hour by 3,412 to get kilowatts of heat. The 33,750 BTU/h starting result is about 9.9 kW of heat, and 23,625 BTU/h is about 6.9 kW. These are heat outputs, not the electricity the heat pump draws, so check the electrical rating with the manufacturer.
Surface-area rules and volume methods compared
Heat pump guides size a pool in three ways: by surface area, by a chart of pool volume, or by the heat needed to warm the water in a set number of hours. The results differ a lot, so it helps to see where this calculator sits.
The surface-area rule of 12
Poolonomics gives a precise method of surface area × temperature rise × 12. Its example is a 16 ft by 32 ft pool, 512 ft², heated from 65°F to 80°F: 512 × 15 × 12 = 92,160 BTU. For this calculator’s starting pool, 450 × 15 × 12 is 81,000 BTU/h, which is 2.4 times the 33,750 BTU/h the calculator returns with its factor of 5.
The volume method with heating hours
Budget Heating works from the water instead. Multiply the gallons by 8.34 and by the temperature rise, then divide by the hours the heat pump can run. For 15,000 gallons raised 10°F that is 1,251,000 BTU, or about 52,100 BTU/h over 24 hours and about 26,100 BTU/h over 48 hours. It leaves out heat loss from the surface.
Where this calculator sits
The factor of 5 gives the low end of these methods. The calculator’s own note says it is lower than a gas heater would use because a heat pump runs for long periods. If you want fast heating or the pool is exposed, choose a larger unit and compare the supplier’s rated output at your air and water temperatures.
How do you work out pool volume?
For the volume method, multiply length by width by average depth and by 7.48 gallons per cubic foot. Budget Heating adds that a pool with a uniform slope has an average depth equal to the shallow and deep ends added together and halved. A 16 ft by 32 ft pool holds about 15,000 gallons at an average depth of roughly 3.9 ft (512 × 7.48 × 3.9).
Climate, season and swim temperature
The calculator cannot see your weather, and it matters. Poolonomics says heat pumps work best from May to September, that most owners want 82°F to 86°F water, and that below about 50°F air temperature a heat pump is pointless.
Should you oversize the heat pump?
Poolonomics recommends sizing up as far as the budget allows, because a larger unit heats faster and runs for fewer hours. A smaller unit still works but runs longer and may struggle to hold the temperature. The price is a higher purchase cost.
What does a cover and swim time change?
Most heat leaves through the surface, so a cover lets you use a smaller pump less often. Poolonomics suggests keeping the pool uncovered for no more than about 2 hours a day. Here the cover cuts the result by 30 percent.
What about electrical supply?
Poolonomics says a heat pump needs 50 to 60 amps, so check your panel and circuit before you pick a size.
Shade, wind and ageing, which only a heat balance covers
EcoOnline’s pool calculator runs a full heat balance. It treats shading as a share of the pool: if half the pool is shaded for half the day, that is 25 percent. It also derates a heat pump by about 20 percent over 10 years. This calculator uses none of that, so a shaded, windy or older system needs a larger margin than the result shows.
Frequently asked questions
What size heat pump do I need for a 15,000-gallon pool?
This calculator works from surface area, not volume. A 16 ft by 32 ft pool has 512 ft², so a 15°F rise gives 38,400 BTU/h uncovered or 26,880 covered. Poolonomics lists 90,000 BTU for 15,000 gallons, so check with a supplier.
How do you calculate pool heat pump size from surface area?
Multiply the surface area by the temperature rise and by a factor. This calculator uses 5 and takes 30 percent off for a cover. Poolonomics uses 12.
Is it better to oversize a pool heat pump?
Poolonomics recommends it, because a bigger unit heats faster and runs less. The cost is a higher purchase price, and the unit still needs a suitable electrical supply.
Does a pool cover let me use a smaller heat pump?
Yes. Most heat is lost from the surface, and the calculator cuts the result by 30 percent when a cover is used.
How do I size a pool heat pump by volume and warm-up time?
Multiply gallons by 8.34 and by the temperature rise, then divide by the hours the pump can run. 15,000 gallons raised 10°F over 48 hours needs about 26,100 BTU/h.
At what air temperature does a pool heat pump stop working well?
Poolonomics says a heat pump is pointless below about 50°F air temperature and works best from May to September. Output drops as the air cools.