A tankless water heater is sized by flow rate and temperature rise, and this tankless water heater sizing calculator works out the GPM your fixtures demand, the burner size that flow needs and whether a unit’s first-hour rating or recovery rate meets your peak demand. Enter how many fixtures run at once, the flow of each and the temperature rise, and the calculator returns the flow in gallons per minute and an approximate burner size in BTU/h. For a storage tank instead, use the water heater sizing calculator.
Tankless Water Heater Sizing Calculator
Recommended flow rate (GPM) for a tankless water heater from simultaneous fixture demand, plus first-hour rating and recovery-rate checks.
The starting values are 2 fixtures at 2.5 GPM each and a 70°F rise.
How do you size a tankless water heater?
Add the flow of every fixture that runs at the same time, then find the temperature rise and the heat needed to deliver that flow. The calculator has three tabs, for flow rate, first-hour rating and recovery rate.
Flow rate and burner size
GPM = Fixtures running at once × GPM per fixture
Burner size (BTU/h) ≈ GPM × 500 × Temperature rise (°F)
Where 500 is the 8.33 lb per gallon of water times 60 minutes an hour, and the rise is the target temperature minus the incoming water temperature. With the starting values, GPM = 2 × 2.5 = 5, and the burner size is 5 × 500 × 70 = 175,000 BTU/h.
How much does temperature rise change the size?
| Inlet temperature | Rise at 120°F | Burner for 5.5 GPM |
|---|---|---|
| 75°F | 45°F | 123,750 BTU/h |
| 65°F | 55°F | 151,250 BTU/h |
| 45°F | 75°F | 206,250 BTU/h |
| 35°F | 85°F | 233,750 BTU/h |
Worked examples for different homes
Worked examples
A cold-climate check
At the starting 5 GPM, a 48°F rise needs 5 × 500 × 48 = 120,000 BTU/h, while a 73°F rise needs 182,500 BTU/h. Use the colder case.
First-hour rating and recovery rate
The first-hour tab compares a unit’s first-hour rating with your peak-hour hot water need. With the starting values of 80 gallons needed and an 84 gallon rating, the margin is 84 − 80 = 4 gallons. The recovery tab gives gallons per hour from the burner input, rise and efficiency.
Recovery (gal/hr) = (BTU/h × Efficiency) ÷ (8.33 × Rise)
With 199,000 BTU/h, a 70°F rise and 95% efficiency, 199,000 × 0.95 = 189,050, and 8.33 × 70 = 583.1, so recovery is 189,050 ÷ 583.1 = 324.2 gal/hr, or 5.4 GPM. That is slightly above the 5 GPM starting demand.
How the number of fixtures and efficiency change the result
The first table keeps the 2.5 GPM per fixture and the 70°F rise and changes the number of fixtures that run at the same time.
| Fixtures at once | Flow | Burner size |
|---|---|---|
| 1 | 2.5 GPM | 87,500 BTU/h |
| 2 | 5.0 GPM | 175,000 BTU/h |
| 3 | 7.5 GPM | 262,500 BTU/h |
Each extra fixture adds 87,500 BTU/h of burner size, so deciding how many fixtures will run together is the most important input. Count the showers, the dishwasher and the washing machine that can run at the same time, and use the flow rating on each fixture label.
Efficiency and recovery
The recovery tab depends on efficiency. With 199,000 BTU/h and a 70°F rise, a 90% efficient unit recovers 307.2 gal/hr, or 5.12 GPM, a 95% unit recovers 324.2 gal/hr, or 5.40 GPM, and a 98% unit recovers 334.5 gal/hr, or 5.57 GPM. A higher efficiency raises the flow a little, so the burner size matters more than the efficiency when you choose between units.
Comparing first-hour ratings
On the first-hour tab, an 84 gallon rating covers a peak-hour need of 60 gallons with a margin of 24 gallons and a need of 80 gallons with a margin of 4 gallons. A need of 100 gallons leaves a shortfall of 16 gallons, which means the unit is too small for that peak hour.
Frequently asked questions
How do I turn GPM into BTU/h?
Multiply GPM by 500 and by the rise. 5.5 GPM at a 70°F rise is 192,500 BTU/h before efficiency losses.
What is a first-hour rating?
It is the hot water a unit can deliver in a busy hour. Compare it with your peak-hour need, such as 84 gallons against 80 gallons.
How many fixtures should I count?
Count the ones that can run at the same time, such as two showers and a dishwasher, and use the flow rating on each fixture.
Does efficiency change the recovery rate?
A little. At 199,000 BTU/h and a 70°F rise, 90% gives 307.2 gal/hr and 98% gives 334.5 gal/hr.
What does a negative margin mean on the first-hour tab?
The rating is below your peak-hour need. A need of 100 gallons against an 84 gallon rating is 16 gallons short.