A whole-house fan is sized by airflow, and this whole house fan size calculator turns your floor area into a recommended CFM (cubic feet per minute). Enter the conditioned floor area and a CFM per square foot, and it gives the airflow to look for on the fan’s rating plate.
Whole House Fan Size Calculator
Recommended whole-house fan airflow (CFM) from total home floor area, for attic/whole-house ventilation.
The starting values are 2,000 ft² of floor area at 2.5 CFM per ft², which give 5,000 CFM. The rate is an input you choose, and the comparison further down shows why 2.5 may be on the low side.
How do you size a whole house fan?
Multiply the floor area by the CFM per square foot. The calculator uses floor area only, so it does not know your ceiling height.
Recommended airflow (CFM) = Floor area (ft²) × CFM per ft²
Where the floor area is the conditioned living space, and the CFM per ft² is the rate you pick.
Worked example: the starting values
Recommended airflow = 2,000 × 2.5 = 5,000 CFM
A fan rated at 5,000 CFM or more would meet that figure.
What CFM per square foot should you use?
Three rates compared
For the 2,000 ft² example with 8 ft ceilings, the volume is 2,000 × 8 = 16,000 ft³. Each rate gives a different airflow and a different air change rate.
The default of 2.5 is 0.5 CFM per ft² below the rule-of-thumb minimum of 3, which is 1,000 CFM or 20% less airflow on this house. It is not wrong to enter 2.5, but it is better to start at 3, and 4 if you want the faster two-minute exchange. The calculator makes no ceiling height adjustment. A 9 ft ceiling holds 9 ÷ 8 = 1.125 times the air of an 8 ft one, so for tall ceilings choose the higher rate.
How much attic venting does the fan need?
| Fan airflow | Attic exhaust area needed |
|---|---|
| 5,000 CFM | 6.67 ft² |
| 6,000 CFM | 8 ft² |
| 8,000 CFM | 10.67 ft² |
The calculator does not work this out, so divide the fan’s CFM by 750 yourself. The house also needs a ready supply of replacement air, such as open windows or doors, and gives no rule for the window area.
Worked examples for different homes
Worked examples
A smaller home at the published minimum
An 1,800 ft² home with 8 ft ceilings at 3 CFM per ft² needs 1,800 × 3 = 5,400 CFM. Its volume is 1,800 × 8 = 14,400 ft³, so the air change rate is 5,400 ÷ 14,400 = 0.375 a minute. The attic needs 5,400 ÷ 750 = 7.2 ft² of free exhaust area.
The same home at the two-minute rate
Using 4 CFM per ft² on the same 1,800 ft² house gives 1,800 × 4 = 7,200 CFM, one full air change every two minutes.
Using conditioned area only
Use the conditioned, occupied floor area, not unfinished basement or attic space, because those are not the rooms the fan is meant to cool. Enter the area in the units your calculator shows and keep the same units for the rate.
What the calculator does not tell you
It does not account for your climate, your ceiling height, the number of open windows or the fan’s noise. A fan works best where evenings and mornings are cooler than the day, because it draws in outdoor air, and it does little in humid or hot-night climates. Treat the CFM as a starting point and check the fan’s rating and the manufacturer’s venting guidance before you buy.
Planning the replacement air
A whole house fan pulls air out through the attic, so the house needs open windows or doors on the other side to let air in. Open the windows in the rooms you want to cool, and open the ones furthest from the fan, so that the air passes through the whole house before it reaches the fan. Close them again when the fan is off, and cover the fan opening in winter to stop heat escaping into the attic.
Frequently asked questions
Does ceiling height matter?
Yes. The calculator uses floor area only, and a 9 ft ceiling holds 1.125 times the air of an 8 ft ceiling, so choose a higher rate for tall rooms.
Should I include the basement or attic in the floor area?
Use the conditioned, occupied floor area. Unfinished basement and attic space are not the rooms the fan cools.
Can a whole house fan replace air conditioning?
Rarely in full. It suits places with cool evenings and mornings, and it does little in hot, humid climates or where nights stay warm.