Size a swamp cooler, also called an evaporative cooler, from the length, width and ceiling height of the space and your climate. The result is the airflow in CFM.
Swamp Cooler Size Calculator
Recommended evaporative (swamp) cooler airflow (CFM) from home volume and climate, for indoor or outdoor cooling.
Starting values: a space of 40 ft by 30 ft with a 10 ft ceiling in a dry climate. The calculator gives 8,000 CFM.
How the calculator works
Volume = length × width × height
CFM = volume ÷ minutes per air change
The minutes per air change depend on the climate you choose:
- Humid: 3 minutes, which is 20 air changes per hour.
- Moderate: 2 minutes, which is 30 air changes per hour.
- Dry or desert: 1.5 minutes, which is 40 air changes per hour.
The three inputs have unit selectors, so you can use feet or metres. The calculator note says the air change interval is a general rule of thumb, and that drier climates use faster air change rates for effective cooling. A federal energy guide says the same, that manufacturers generally aim for 20 to 40 air changes per hour depending on the climate.
Worked examples
The same space in three climates
A space of 40 ft by 30 ft by 10 ft has a volume of 12,000 ft³.
- Dry: 12,000 ÷ 1.5 = 8,000 CFM.
- Moderate: 12,000 ÷ 2 = 6,000 CFM.
- Humid: 12,000 ÷ 3 = 4,000 CFM.
A house
A house of 1,500 ft² with 8 ft ceilings has a volume of 12,000 ft³, and gives the same results as above. In a dry climate, that is 8,000 CFM.
A small room
A room of 20 ft by 15 ft with an 8 ft ceiling has a volume of 2,400 ft³. In a dry climate, 2,400 ÷ 1.5 = 1,600 CFM.
Where swamp coolers work
The energy guide explains that an evaporative cooler pulls outdoor air through wet pads, and that the evaporation cools the air by about 15 to 40°F before it enters the home. It works well in dry, low-humidity areas, and two-stage models suit places where the daytime highs often pass 100°F. Because it adds moisture to the air, it is a poor fit for humid regions, and a humid-climate result from the calculator is a size, not a recommendation to buy one.
Ventilation is part of the design
Unlike central air, which recirculates indoor air, an evaporative cooler constantly brings in fresh air. Windows must be partly open to let the warm indoor air out. The guide advises about 1 to 2 ft² of opening per 1,000 CFM of capacity, on the side of the house away from the wind. For 8,000 CFM, that is about 8 to 16 ft² of openings. Too little opening lets humidity build up, and too much lets in hot air.
Choosing the unit
Units are rated in CFM, and the guide says they typically range from about 3,000 to 25,000 CFM. Compare the result with the rating of a real unit, and choose a unit at or a little above the result. A small room like the 1,600 CFM example is below that range, so look at smaller portable units for it.
Running costs and care
The guide says an evaporative cooler costs about half as much to install as central air and uses roughly a quarter of the energy, and that it needs a continuous water supply, which can be a problem where water is scarce. It also needs maintenance: check the pads, filters, reservoir and pump monthly in a hot climate, replace the pads twice a season, and drain and clean the unit each season.
Related calculators
For other ways of cooling, see the mini split calculator and the whole house fan size calculator. To find the volume of a room, see the room volume calculator.
Checking your result
Compare the calculator figure with the rating of the cooler you are considering. A unit with a higher CFM than you need still works, because you can run it at a lower speed, but a unit that is too small will not cool the space on a hot day. If your result falls between two sizes, the larger one gives a margin on the hottest days.
Open spaces and rooms with high ceilings
The calculator uses the full volume, so a tall ceiling raises the result. A space of 40 ft by 30 ft with a 14 ft ceiling has a volume of 16,800 ft³, and in a dry climate it needs 11,200 CFM. If only the lower part of the room needs cooling, such as the occupied zone, a smaller unit may be enough, but the calculator does not do that adjustment.
Outdoor and open areas
The calculator is for a closed space with a means of letting air out. In an open patio or a space with large open doors, the cooled air leaves quickly, so cooling is local to the area near the unit. A cooler in that setting cools the spot nearby and not the whole space, so size it for the area that you want to cool.
Frequently asked questions
What size swamp cooler do I need?
Find the volume of the space and divide it by the minutes per air change, which is 1.5 for a dry climate, 2 for moderate and 3 for humid. A space of 12,000 ft³ in a dry climate needs 8,000 CFM.
How many air changes per hour does a swamp cooler need?
A federal energy guide says manufacturers generally aim for 20 to 40 air changes per hour, depending on the climate. The calculator uses 20, 30 and 40.
Do I need to open windows with a swamp cooler?
Yes. Windows must be partly open to let warm air out. The guide advises about 1 to 2 ft² of opening per 1,000 CFM.
Do swamp coolers work in humid climates?
They work best in dry climates, because they add moisture to the air. They are a poor fit for humid regions.