To find the minimum drawdown needed, multiply your well pump’s flow rate by the minimum run time you want per cycle; the approximate tank size is about three times that drawdown figure.
Well Pressure Tank Size Calculator
Recommended pressure tank drawdown capacity for a well pump, from pump flow rate and desired minimum run time between cycles.
Sizing a Well Pressure Tank From Pump Flow Rate
A pressure tank’s usable drawdown — the volume of water it delivers before the pump kicks back on — should be large enough to give the pump a reasonable minimum run time per cycle, since pumps that cycle on and off too frequently wear out faster. This calculator estimates the minimum drawdown needed from your pump’s flow rate and desired run time, then estimates the approximate total tank size needed, since a standard bladder tank’s usable drawdown is roughly a third of its total volume.
This covers related searches such as well pressure tank size calculator, how to size a pressure tank for a well pump, and pressure tank drawdown calculation.
How the Well Pressure Tank Size Calculator Works
Minimum drawdown needed = Pump flow rate (GPM) × Minimum run time per cycle (minutes)
Approximate tank size = Minimum drawdown × 3
A standard bladder tank’s usable drawdown is roughly a third of its total volume — check your tank’s data sheet for its exact drawdown rating, since this varies by tank design.
Worked Example
A 10 GPM pump with a desired 1-minute minimum run time per cycle: Minimum drawdown needed = 10 × 1 = 10 gallons. Approximate tank size = 10 × 3 = 30 gallons.
Frequently Asked Questions
Why does pump run time matter for tank sizing?
Well pumps that cycle on and off too frequently (short-cycling) experience more wear and can fail prematurely, so sizing the tank to give the pump an adequate minimum run time per cycle helps extend pump life.
What is drawdown, exactly?
Drawdown is the volume of water a pressure tank delivers between the pump’s cut-in and cut-out pressure settings — it’s the usable water volume, not the tank’s total physical capacity.
Why is drawdown only about a third of total tank volume?
Standard bladder or diaphragm pressure tanks hold a pre-charged air cushion alongside the water, and only the portion of water that moves between the pump’s pressure switch settings counts as usable drawdown — this ratio varies by tank design, so check your specific tank’s data sheet.
What minimum run time should I target?
Pump manufacturers often specify a minimum recommended run time per cycle for their specific pump model — check your pump’s documentation rather than assuming a single universal figure.
Does a bigger tank always mean better performance?
A larger tank generally reduces cycling frequency and can improve pump longevity, but it also costs more and takes up more space, so the right size balances your pump’s needs against practical space and budget constraints.
Can I use this calculator for a constant-pressure pump system?
Constant-pressure (variable-speed) well pump systems sometimes use smaller tanks since the pump modulates speed rather than cycling on/off in the same way — check your specific system’s manufacturer guidance for tank sizing recommendations.
How do I find my well pump’s flow rate?
Your pump’s flow rate (in GPM) is typically listed on its data plate or in its installation manual — if you don’t have this information, a well or pump contractor can measure it directly.