A well pressure tank has to store enough water that the pump does not switch on and off every few seconds. This well pressure tank size calculator multiplies the pump’s flow rate in GPM by the minimum run time you want to get the drawdown, then multiplies the drawdown by three to estimate the tank size.
Well Pressure Tank Size Calculator
Recommended pressure tank drawdown capacity for a well pump, from pump flow rate and desired minimum run time between cycles.
The starting values are a 10 GPM pump and a 1 minute run time, giving 10 gallons of drawdown and a 30 gallon tank.
How is the well pressure tank size calculated?
Drawdown is the water the tank delivers between the pump switching off and switching on again.
Drawdown (gal) = Pump flow (GPM) × Minimum run time (min)
Approximate tank size (gal) = Drawdown × 3
The factor of 3 assumes the usable drawdown is about a third of the tank’s total volume. The calculator’s own note says to check the tank’s data sheet.
Worked example: the starting values
Drawdown = 10 × 1 = 10 gal
Tank size = 10 × 3 = 30 gal
How pump flow and run time change the tank size
Both inputs multiply, so the table keeps a 1 minute run time and changes the pump flow.
| Pump flow | Drawdown | Approximate tank size |
|---|---|---|
| 8 GPM | 8 gal | 24 gal |
| 10 GPM | 10 gal | 30 gal |
| 12 GPM | 12 gal | 36 gal |
| 15 GPM | 15 gal | 45 gal |
A longer run time
A longer minimum run time means fewer starts. With a 10 GPM pump, run times of 1, 1.5 and 2 minutes need drawdowns of 10, 15 and 20 gallons and approximate tank sizes of 30, 45 and 60 gallons. A pump with a 12 GPM flow and a 2 minute run time needs 24 gallons of drawdown and a tank of about 72 gallons.
Why the run time matters
A pump that starts and stops often wears its motor and its control parts faster than one that runs for longer cycles, and the tank is what sets the cycle length. A larger tank costs more, so the run time is a trade between the price of the tank and the wear on the pump. Pump makers give a minimum run time in their data sheets, so use that figure if you have one.
From the estimate to a real tank
The result is an approximate total volume, and the drawdown of a real tank depends on its size and on the pressure switch setting. Compare the estimate with the data sheet of the tank you are considering, and choose a tank whose drawdown at your setting is at least the figure the calculator gives. Tanks come in set sizes, so you will usually round up to the next one.
A worked sizing example
Suppose the pump delivers 12 GPM and the maker asks for a minimum run time of 1.5 minutes. The drawdown is 12 × 1.5 = 18 gallons, and the approximate tank volume is 18 × 3 = 54 gallons. A tank in the next size up would be chosen, for example one whose data sheet shows at least 18 gallons of drawdown at your pressure setting. If the household often runs several fixtures at once, the pump flow goes up and so does the tank, so use the flow of the pump you have, not the flow of a single tap.
What to check on the data sheet
Look for the drawdown figure at the pressure switch setting you will use, such as a 40/60 or a 30/50 setting. The same tank gives a different drawdown at each setting, and the calculator’s factor of three is only an average. Check the maximum working pressure too, and that the connection suits the plumbing you have.
Signs that the tank is too small
A tank that is too small makes the pump start and stop every few seconds when you run water, and the pressure may pulse at the tap. If you notice this, check the air charge first, since a tank that has lost its air charge behaves like one that is too small, before you decide to replace it.
Frequently asked questions
How do I size a well pressure tank?
Multiply the pump’s GPM by the minimum run time to get the drawdown, then choose a tank whose drawdown at your pressure setting is at least that.
What is drawdown?
The water a tank delivers between the pump switching off and switching on again.
What run time should I use?
Use the minimum run time in the pump maker’s data sheet. If you have none, a longer run time means fewer starts but a larger tank.
How big a tank does a 12 GPM pump need?
With a 1 minute run time the estimate is 36 gallons, and with a 2 minute run time it is 72 gallons.
Does the pressure setting matter?
Yes. The drawdown a tank gives depends on the switch setting, so check the tank’s data sheet against the calculator’s drawdown figure.