A chimney liner has to be matched to the appliance that vents into it. Enter the appliance input rating and its fuel type, and this calculator returns a rough starting diameter that you should then check against the manufacturer’s sizing rules.
Chimney Liner Sizing Calculator
Recommended chimney liner diameter for a fireplace or appliance flue, from appliance BTU input and flue type.
Starting values: the calculator opens with an appliance rating of 100,000 BTU per hour and a wood fireplace or stove. It returns a liner diameter of about 2.91 in. Read the sections below before relying on the number.
The formula
Flue area = Appliance input ÷ Rate for the fuel
Diameter = 2 × √(Flue area ÷ π)
Where:
- Appliance input = the BTU per hour rating you enter
- Rate for the fuel = 15,000 BTU per hour for each square inch for wood, 20,000 for gas and 18,000 for oil
- Flue area = the cross-section of the liner in square inches
The calculator’s own note calls this a simplified area-based estimate and says to confirm it against the appliance maker’s and the liner maker’s sizing tables.
Worked examples
Example 1: the default
100,000 ÷ 15,000 = 6.67 sq in. The diameter is 2 × √(6.67 ÷ 3.1416) = 2 × 1.457 = 2.91 in.
Example 2: the same rating for each fuel
At 100,000 BTU per hour, gas gives 100,000 ÷ 20,000 = 5.0 sq in and a diameter of 2.52 in, and oil gives 100,000 ÷ 18,000 = 5.56 sq in and 2.66 in.
Example 3: a larger wood appliance
At 150,000 BTU per hour, wood gives 150,000 ÷ 15,000 = 10 sq in and a diameter of 3.57 in.
Example 4: converting a diameter to an area
Area = π × (Diameter ÷ 2)². A 6 in liner has an area of 3.1416 × 9 = 28.3 sq in, and an 8 in liner has 50.3 sq in. You need this to compare a round liner with the opening on the appliance.
An important limit of this calculator
The results are small compared with the liners normally used on stoves and fireplaces. A 6 in liner has more than four times the area the calculator gives for the default 100,000 BTU per hour wood appliance. I found no published source for the BTU-per-square-inch rates in the formula, so treat the output as a rough lower bound and never as a purchasing size. The rules below, from a chimney-sweep guide, are the ones to follow.
How liners are really sized
- Stainless steel liners. Use the same size as the exhaust opening on the appliance.
- Masonry liners. The cross-sectional area should be at least the area of the appliance’s exhaust opening and no more than three times that area. An oversized liner can weaken the draft and encourage creosote.
- Chimneys on an outside wall. If one face is exposed to the cold for its whole length, the liner should be no more than twice the exhaust collar’s area.
- Manufacturer listings. Appliance makers may have a specific listing for their model in the installation manual, which can be accepted in place of the standard rules.
- Local code. Authorities may modify these standards, so check with yours.
An example with a 6 in collar
A stove with a 6 in exhaust collar has an area of 28.3 sq in. A stainless liner would be 6 in. A masonry liner would need to be between 28.3 and 84.8 sq in, and no more than 56.5 sq in on a chimney with a cold outside wall. The calculator’s 2.91 in would be far below any of these.
What else affects sizing
The calculator’s note says sizing also depends on the appliance type, the height of the flue, offsets and local code. A tall straight flue draws differently from a short one with bends, so a rating alone cannot fix the size.
Before you buy
- Read the appliance manual for the flue collar size and any listed liner.
- Measure the existing flue and note the height and any offsets.
- Ask the liner maker for a sizing chart for your fuel and appliance.
- Have a qualified installer inspect the chimney, since a liner is a safety item.
What the calculator does not do
- It does not read the appliance’s flue collar. That size, not this estimate, governs the liner.
- It does not know the height of the chimney, offsets or the climate.
- It does not choose a liner material or give a code answer.
- It gives a round diameter and not the size of a rectangular flue.
To estimate how much heat a room needs, use the room BTU calculator.
Reading the result safely
Because the calculator’s numbers sit well below real liner sizes, the safest way to use it is as a comparison and not as a specification. Work out the area of the appliance’s exhaust collar from its diameter, then compare that with what the calculator says. If the collar is far larger, as it will be for most stoves, the collar wins.
Example 5: comparing the two numbers
A wood stove rated at 60,000 BTU per hour gives 60,000 ÷ 15,000 = 4.0 sq in, a diameter of 2.26 in. A stove of that rating typically still has a collar much wider than that, so a 2.26 in liner would choke it. The collar diameter in the manual is the number to follow.
Example 6: area limits for a masonry flue
For an 8 in collar, the area is 3.1416 × 16 = 50.3 sq in. A masonry liner would then be between 50.3 and 150.8 sq in, and an outside-wall chimney would be capped at 100.5 sq in. Divide each area by π and take the square root to turn it back into a diameter.
Example 7: converting an area back to a diameter
Diameter = 2 × √(Area ÷ π). For 100.5 sq in that is 2 × √32.0 = 11.3 in. So a round flue of about 11.3 in is the largest that rule allows with an 8 in collar on an outside wall.
When to call a professional
Relining a chimney is a safety job. A poorly sized or poorly fitted liner can let smoke or carbon monoxide into the house, so have a qualified installer or chimney sweep inspect the flue and confirm the size before you buy. Treat this page as a way to understand the numbers, not as the final word.
Frequently asked questions
How do I size a chimney liner?
Use the appliance manufacturer’s sizing rules. For a stainless liner that usually means the same size as the appliance’s exhaust opening, and for masonry the area should be between one and three times that opening.
Why does the calculator give such a small diameter?
It uses a simplified BTU-per-square-inch estimate, and I found no published source for its rates. Treat the result as a rough lower bound and check the appliance collar.
Can a liner be too big?
Yes. An oversized liner can weaken the draft and encourage creosote, so masonry liners are limited to three times the collar area, or twice on an outside-wall chimney.
Does the fuel type matter?
The calculator uses different rates for wood, gas and oil, and real installations differ by fuel, so check the manual for your appliance.