Welding Heat Input Calculator (kJ/mm)

This heat input calculator works out welding heat input in kJ/mm from arc voltage, welding current and travel speed, with an efficiency factor you set for the process.

Rates Calculators

Heat Input Calculator

Welding heat input (kJ/mm), from arc voltage, current, and travel speed.

V
A
mm/min
%
Commonly cited approximate values: ~100% SAW, ~80–85% GMAW/SMAW, ~60–70% GTAW — enter the value appropriate to your process/code.
Thermal efficiency factors are process-dependent (and code-specific, e.g. AWS D1.1) — confirm the correct factor for your welding process and applicable code before using this for procedure qualification.

Starting values: the calculator opens with 24 V, 180 A, a travel speed of 300 mm/min and an efficiency of 100 percent. That gives 0.864 kJ/mm. Change the efficiency to 80 percent and the result drops to 0.691 kJ/mm.

The formula

Heat Input (kJ/mm) = (Voltage × Current × 60) ÷ (Travel Speed × 1,000) × Efficiency

Where:

  • Voltage = arc voltage in volts
  • Current = welding current in amps
  • Travel Speed = how fast the arc moves along the joint, in mm/min
  • 60 = converts the travel speed from minutes to seconds
  • 1,000 = converts joules to kilojoules
  • Efficiency = the process (thermal) efficiency, entered as a percentage

The part before the efficiency factor, voltage times current divided by speed, is called the arc energy. It is the electrical energy delivered per unit length of weld. Multiplying by the efficiency gives the heat input that actually enters the work. The Welding Institute describes it in the same terms: heat input equals the process efficiency times the arc energy, which is defined by the voltage, current and travel speed.

Arc energy versus heat input

The terms are used differently in different places. The Welding Institute notes that a number of American codes use the term heat input when they actually mean arc energy, which has no efficiency factor. Because the calculator defaults to 100 percent efficiency, its first result is the arc energy. If your code or procedure asks for heat input with an efficiency factor, change the efficiency field. If it asks for arc energy, leave it at 100.

Choosing the efficiency

The efficiency factor depends on the welding process. The Welding Institute gives factors relative to submerged arc welding at 1.0: 0.8 for manual metal arc (stick) welding, 0.8 for MIG and MAG welding, and 0.6 for TIG welding. It notes that laser welding does not use an efficiency factor. The calculator’s own hint gives approximate ranges instead: about 100 percent for submerged arc, 80 to 85 percent for gas metal arc and stick welding, and 60 to 70 percent for TIG welding. The sources agree on the order and the rough size, but not on exact values, so enter the factor named in your welding procedure or the code that applies to your job.

Welding codes differ on which factors to use, and procedure qualification depends on the code. Treat the calculator as an arithmetic tool and confirm the factor before you rely on the result for qualification.

Worked examples

Example 1: the default

  1. Voltage × current = 24 × 180 = 4,320 watts.
  2. Multiply by 60: 4,320 × 60 = 259,200.
  3. Divide by speed × 1,000 = 300 × 1,000 = 300,000. The result is 0.864 kJ/mm.
  4. With efficiency of 100 percent, heat input is 0.864 kJ/mm.

Example 2: with an 80 percent efficiency

Take the same figure and multiply by 0.8. 0.864 × 0.8 = 0.691 kJ/mm.

Example 3: a MIG weld

Voltage is 28 V, current 220 A and travel speed 250 mm/min, with an efficiency factor of 0.8. Arc energy = 28 × 220 × 60 ÷ (250 × 1,000) = 369,600 ÷ 250,000 = 1.478 kJ/mm. Heat input = 1.478 × 0.8 = 1.183 kJ/mm.

Example 4: a TIG weld

Voltage is 12 V, current 150 A and travel speed 100 mm/min, with a factor of 0.6. Arc energy = 12 × 150 × 60 ÷ 100,000 = 1.08 kJ/mm. Heat input = 1.08 × 0.6 = 0.648 kJ/mm.

Units and conversions

The result is in kJ/mm, the unit used in Europe. Codes in North America commonly use kJ/in. To convert, multiply kJ/mm by 25.4. The default 0.864 kJ/mm is about 21.9 kJ/in. If your travel speed is in inches per minute, multiply by 25.4 to get mm/min before you enter it.

What changes the heat input

  • Higher current or voltage raises it, since more power goes into the joint.
  • Faster travel lowers it, because the same power is spread over a longer length.
  • A higher efficiency factor raises it for the same electrical settings.

Heat input matters because it affects the cooling rate and the properties of the weld and the heat-affected zone. Many procedures set a minimum or maximum for it. Check the limits in your own procedure rather than assuming a number.

Reading the result against a limit

Procedures often give a heat input window rather than a single target. Suppose a procedure allows 0.8 to 1.2 kJ/mm and you are welding at 24 V and 180 A with an efficiency of 0.8. At 300 mm/min the result is 0.691 kJ/mm, which is below the window. Slowing the travel speed raises the heat input: at 200 mm/min it becomes 24 × 180 × 60 ÷ 200,000 × 0.8 = 1.037 kJ/mm, inside the window. Because the speed is in the denominator, a lower speed gives a proportionally higher result. This is the quickest way to see which setting to change.

Checking your own measurements

Use measured values where you can. The voltage and current shown on the machine are not always the values at the arc, and travel speed is best found by timing a run over a measured length. If you weld 150 mm in 30 seconds, the travel speed is 150 ÷ 0.5 = 300 mm/min, the default in the calculator. Small errors in speed matter, since heat input is inversely proportional to it.

Frequently asked questions

What is the heat input formula for welding?

Heat input in kJ/mm equals voltage times current times 60, divided by travel speed in mm/min times 1,000, multiplied by the process efficiency.

What efficiency should I enter?

Use the factor given by your welding procedure or applicable code. Common values are around 0.8 for stick and MIG or MAG welding and about 0.6 for TIG welding. Submerged arc welding is taken as 1.0.

What is the difference between arc energy and heat input?

Arc energy is voltage times current divided by travel speed. Heat input is that figure multiplied by the process efficiency. Some codes use the term heat input where they mean arc energy.

How do I convert kJ/mm to kJ/in?

Multiply by 25.4. A heat input of 0.864 kJ/mm is about 21.9 kJ/in.