AC Wattage Calculator: BTU to Watts & Electrical Load

This AC wattage calculator shows how much electrical power an air conditioner draws. Enter its cooling capacity and EER, or switch to the general mode and enter volts, amps and power factor for any load.

Rates Calculators

AC Wattage Calculator

Power draw (watts) for an air conditioner from its cooling capacity and efficiency rating, or for any electrical load from volts, amps and power factor.

BTU/h or tons
Found on the unit's nameplate or spec sheet; typical window/split units are often in the 8–13 EER range.

Starting values: the AC mode opens with 12,000 BTU/h and an EER of 10, which gives 1,200 W. The split AC mode opens with 1.5 tons and an EER of 12, giving 18,000 BTU/h and 1,500 W. The general mode opens with 120 V, 10 A and a power factor of 1, which gives 1,200 W.

Three ways to find the wattage

The calculator has three modes, so you can start from whatever the label or the specification sheet gives you.

  • AC unit: enter the cooling capacity in BTU/h or in tons, plus EER.
  • Split AC: enter the capacity in tons and EER. It also converts the tonnage to BTU/h.
  • General electrical load: enter voltage, current and power factor for any appliance.

The formulas

Watts = Cooling capacity (BTU/h) ÷ EER
Cooling capacity (BTU/h) = Tons × 12,000
Watts = Volts × Amps × Power factor

Where:

  • BTU/h = the cooling capacity of the unit
  • EER = energy efficiency ratio, the cooling output in BTU per hour for each watt of electrical input
  • Tons = a unit of cooling capacity, where 1 ton equals 12,000 BTU/h
  • Power factor = the ratio of real power to apparent power, between 0 and 1

An engineering reference defines EER as the cooling output divided by the electrical input, measured at steady state with a 95°F outdoor temperature. It also notes that 12,000 BTU/h of cooling at 1,000 W of input corresponds to an EER of 12, which is exactly how the formula above works in reverse.

EER, and why it is not SEER

EER is a steady-state rating at one set of conditions. SEER, the seasonal rating, averages performance over a range of temperatures and is used mainly for central systems. They are not interchangeable. The calculator expects EER. If you only have a SEER, the wattage it gives would be misleading, so look for the EER on the nameplate or specification sheet. The tool’s own hint says typical window and split units are often in the 8 to 13 range for EER. The same reference recommends an EER of at least 9 for mild climates and above 10 for hot ones.

Worked examples

Example 1: the default AC unit

12,000 BTU/h at EER 10 gives 12,000 ÷ 10 = 1,200 W. At 120 V that corresponds to a current of 1,200 ÷ 120 = 10 A.

Example 2: capacity given in tons

A 2-ton unit with EER 11. Choose the tons option and enter 2. Capacity = 2 × 12,000 = 24,000 BTU/h, and power = 24,000 ÷ 11 = 2,182 W.

Example 3: the split AC default

1.5 tons at EER 12. Capacity = 1.5 × 12,000 = 18,000 BTU/h. Power = 18,000 ÷ 12 = 1,500 W.

Example 4: a small room unit

A 5,000 BTU/h room unit with EER 10 draws 5,000 ÷ 10 = 500 W. The reference above puts room units at roughly 5,000 to 15,000 BTU/h.

Example 5: the general load mode

A 230 V appliance draws 6 A at a power factor of 0.9. Power = 230 × 6 × 0.9 = 1,242 W. Use this mode when you have measured the current, or when the label lists volts and amps instead of EER.

From watts to energy

Watts measure power at a moment. Energy is power multiplied by time. A 1,200 W draw for 8 hours is 1,200 × 8 = 9,600 watt-hours, or 9.6 kWh. Multiply by your electricity price per kWh to estimate the running cost. The result assumes the compressor runs continuously. In practice it cycles on and off, so actual energy use depends on how hard the unit works.

Limits to keep in mind

  • The result is the steady-state draw implied by the rated capacity and EER. It does not include the brief start-up surge.
  • The EER is measured at one test condition, so the draw changes with outdoor temperature and load.
  • The calculator does not estimate the capacity you need for a room. For that, see the room BTU calculator.

Sizing the electrical supply

The wattage you calculate is a starting point for checking the supply. Dividing watts by voltage gives the running current: 1,200 W at 120 V is 10 A, and the same 1,200 W at 230 V is about 5.2 A. If the label shows power factor below 1, the current is higher than that simple division suggests, since amps = watts ÷ (volts × power factor). A unit with a power factor of 0.9 and 1,200 W at 120 V draws 1,200 ÷ (120 × 0.9) = 11.1 A.

Start-up current, circuit ratings and local electrical rules decide the actual breaker and wiring. This calculator gives you the running draw, not an installation design, so leave the sizing of the circuit to a qualified electrician.

How efficiency changes the draw

For the same 12,000 BTU/h of cooling, an EER of 10 needs 1,200 W, while an EER of 12 needs 1,000 W. The more efficient unit draws about 17 percent less power for the same output. Over a long cooling season, that gap is the reason EER is worth checking when you compare models.

Frequently asked questions

How many watts does a 12,000 BTU air conditioner use?

Divide the BTU/h by the EER. At an EER of 10 it uses about 1,200 W. A higher EER means fewer watts for the same cooling.

How do I convert tons to BTU/h?

One ton of cooling equals 12,000 BTU/h, so multiply the tons by 12,000. A 1.5 ton unit is 18,000 BTU/h.

Can I use SEER instead of EER?

No. SEER is a seasonal average measured differently. The calculator’s formula uses EER, which you can usually find on the nameplate or in the specification sheet.

What does the general electrical load mode do?

It multiplies voltage, current and power factor to give power in watts. It is useful when you know the amps drawn instead of the efficiency rating.