Wall Header Calculator – Check a Header or Beam for Bending, Shear & Deflection

A wall header carries the load above a door or window opening and passes it to the studs on each side, so it has to be checked for bending, shear and deflection. This wall header calculator checks a solid wood header or beam under a uniform load against your allowable stresses and a deflection limit.

Wall Calculators

Wall Header & Beam Calculator

Check a wood header or load-bearing wall beam for bending, shear and deflection under a uniform load.

Adjusted design value for your species and grade (e.g. NDS Supplement).
Simply supported beam with a uniform load; checks bending, shear (simplified, at the support) and deflection only. Bearing, lateral stability and code load combinations are not checked — have headers for structural walls verified by a qualified professional.

The starting values are a 6 ft clear span, 400 plf of total load, a 3 × 9.25 in section made of two 1.5 in plies, Fb′ of 1,000 psi, Fv′ of 180 psi, E of 1,600,000 psi and an L/360 limit. The result is bending of 505 psi, shear of 65 psi and deflection of 0.037 in, so the header passes.

How is a wall header checked?

The calculator treats the header as a simply supported beam with one uniform load and compares three results with their limits.

M = w × L² ÷ 8
S = b × d² ÷ 6
fb = M ÷ S
V = w × L ÷ 2
fv = 1.5 × V ÷ (b × d)
δ = 5 × w × L⁴ ÷ (384 × E × I), with I = b × d³ ÷ 12

Where w is the total load in plf, L is the clear span, b is the beam width and d is the beam depth. The header passes only when fb is at most Fb′, fv is at most Fv′ and δ is at most the span divided by the limit you choose.

Worked example: the starting values

L = 6 ft = 72 in
M = 400 × 6² ÷ 8 = 1,800 ft-lb = 21,600 in-lb
S = 3 × 9.25² ÷ 6 = 42.78 in³
fb = 21,600 ÷ 42.78 = 505 psi, which is 50% of 1,000
V = 400 × 6 ÷ 2 = 1,200 lb
fv = 1.5 × 1,200 ÷ (3 × 9.25) = 65 psi, which is 36% of 180
I = 3 × 9.25³ ÷ 12 = 197.9 in⁴
δ = 0.037 in against 72 ÷ 360 = 0.2 in, which is 18%

Worked examples for different headers

Worked examples

A longer span

At 8 ft with 400 plf and the same 3 × 9.25 in section, M is 38,400 in-lb. Bending is 898 psi, which is 90% of 1,000, shear is 87 psi and deflection is 0.116 in against 0.267 in. It passes, but bending now leaves little margin.

A span that is too long

At 10 ft the moment is 60,000 in-lb and bending is 1,403 psi, which is 140% of 1,000, so the header fails. Deflection is 0.284 in against 0.333 in, which still passes, so bending is the check that decides.

A deeper section

Using 3 × 11.25 in for the 8 ft span raises S to 63.28 in³. Bending falls to 607 psi, which is 61% of 1,000, and deflection falls to 0.065 in.

Reading the three utilization figures

The result compares each demand with its allowable value and shows how much of the capacity is used. For the starting header the three checks come out as follows.

Check Value Share of the limit used
Bending stress 505 psi 50%
Shear stress 65 psi 36%
Deflection 0.037 in 18%

Bending is the governing check here because it uses the largest share of its limit. A header passes only when all three are at or below 100%, so the highest figure is the one to watch.

What to do when a check fails

If bending is the check that fails, use a deeper member, a stronger grade or a doubled member, or shorten the span. Deflection usually improves most from added depth, since stiffness rises steeply with the depth of the member. A shear failure is less common on residential spans and is often fixed by a larger section or a shorter span.

Whatever the result, a header carries the loads above an opening and its failure is serious. Treat this as a first sizing check and have the final member confirmed by a licensed engineer or your local building department before you build.

Frequently asked questions

How do I check a wall header?

Work out bending stress, shear stress and deflection, then compare each with its limit. For the starting values they are 505 psi, 65 psi and 0.037 in.

How far can a double 2×10 header span?

It depends on load and grade. With the starting load and stresses, 6 ft passes at 505 psi and 8 ft passes at 898 psi, while 10 ft fails at 1,403 psi.

Does the calculator check bearing?

No. It checks only bending, shear and deflection, not compression perpendicular to grain at the supports.

Can I use it for LVL or glulam?

Only if you enter the manufacturer’s adjusted values for that product. This calculator covers solid-sawn 2x lumber only, and a qualified professional should verify structural headers.

Which of the three checks usually governs a wall header?

It is whichever uses the largest share of its limit. In the starting example bending governs at 50%, ahead of shear at 36% and deflection at 18%.

What should I do if the header fails a check?

Use a deeper or stronger member, double it, or shorten the span, then run the numbers again. Have the final choice confirmed by a licensed engineer or your local building department.