This EC50 calculator finds the concentration that produces half of the maximum effect, together with the Hill slope, from your own dose-response data. A second mode works the other way: give it a known EC50 and slope and it returns any ECx value, such as EC10 or EC90, and the response at a chosen concentration.
EC50 Calculator
Estimate EC50 and Hill slope from dose-response data, or find any ECx and the response at a given concentration from EC50 and slope.
Starting values: the data mode opens with six concentration and response pairs, from 0.1 up to 30. They give an EC50 of 3.0026, a Hill slope of 1.1966 and an R² of 0.99998.
What EC50 means
EC50 is the concentration of a substance that gives 50% of its maximum effect. It is the usual way to compare how potent drugs, toxicants and other active compounds are. A lower EC50 means that less of the substance is needed to reach half of the effect. The Hill slope describes how steep the curve is. A slope near 1 gives a gradual rise, and a larger slope gives a sharper switch from little effect to nearly full effect.
How to use the EC50 calculator
Mode 1: EC50 from data
- Enter one pair per line, with the concentration first and the percentage response second, separated by a space, comma or tab.
- Use the same concentration unit throughout. The EC50 comes back in that unit.
- Read the EC50, the Hill slope, the goodness of fit, EC10 and EC90, and an interpolated EC50 as a second opinion.
Responses must be a percentage of the maximum effect, above 0 and below 100. Concentrations must be greater than zero. You need at least three points that lie strictly between 0% and 100%, because the fit ignores points at the two ends. The responses must rise with concentration, or the calculator reports that the fitted slope is not positive.
Mode 2: ECx from EC50 and slope
Enter the EC50, the Hill slope and the effect level x as a percentage of the maximum effect. You can also enter a concentration, and the calculator then returns the response at that dose.
The formulas
The calculator uses the Hill equation:
Response (%) = 100 / (1 + (EC50 / C)^h)
ECx = EC50 × (x / (100 – x))^(1/h)
Where:
- C = concentration
- EC50 = concentration giving 50% of the maximum effect
- h = Hill slope
- x = effect level in percent, between 0 and 100
In data mode, the fit is a linearised version of this equation. It plots logit(response) against the natural log of concentration, where logit(R) is ln(R / (100 – R)), and fits a straight line by least squares. The slope of the line is h, and the EC50 follows from the intercept. This is a quick and transparent method, and it assumes that the response runs from 0% to 100%.
Worked examples
Example 1: the default data
The six points are (0.1, 1.7), (0.3, 5.9), (1, 21), (3, 50), (10, 81) and (30, 94). The fit gives an EC50 of 3.0026 and a slope of 1.1966, with R² = 0.99998, which means the points sit almost exactly on a straight line in logit form. EC10 is 0.4787 and EC90 is 18.834. Because one of the points is exactly 50%, the interpolated EC50 is 3, found on a log-concentration axis between 1 and 3.
Example 2: EC90 from a known EC50
With EC50 = 3 and a slope of 1.2, the EC90 is 3 × 9^(1/1.2) = 18.72, and the EC10 is 0.4807. The calculator also shows that a concentration of 10 gives 80.9% of the maximum effect.
Example 3: how the slope changes the spread
Keep EC50 = 3 and change only the slope. At h = 1, EC90 = 3 × 9 = 27. At h = 2, EC90 = 3 × 3 = 9, and EC10 falls to 1. A steeper curve packs the range from 10% to 90% effect into a much narrower band of concentrations. Two compounds with the same EC50 can therefore behave very differently near the top and bottom of the curve.
Example 4: reading a response at a chosen dose
With EC50 = 3 and h = 1.2, a concentration of 1 gives 21.1% of the maximum effect, and a concentration of 3 gives exactly 50%. That second value is a quick check that the inputs are consistent.
Checking your result
- R² close to 1 means the points follow the Hill shape. A low value suggests noisy data or a curve that does not fit this model.
- Compare the fitted EC50 with the interpolated EC50. They should be of the same order. A large gap points to scatter in the middle of the curve.
- Check that your data brackets 50%. An EC50 estimated far outside the range of your concentrations is an extrapolation and deserves little trust.
- Keep the unit the same on every line.
Limits of the method
The data fit is a linearised regression, not a four-parameter fit. It assumes the response runs from 0% to 100%, so it does not estimate a bottom or top plateau, and it gives no confidence intervals. It also drops points at 0% and 100%, which can matter if many of your points sit at the extremes. For publication-quality work, or for data where the plateaus are unknown, use dedicated curve-fitting software. This calculator suits screening, checking a spreadsheet and learning how the Hill equation behaves.
Frequently asked questions
What is EC50?
EC50 is the concentration of a substance that produces half of its maximum effect. A lower EC50 means a more potent substance.
How does the calculator estimate EC50 from data?
It fits a straight line to logit(response) against ln(concentration) by least squares, and reads the Hill slope and EC50 from the line.
How many data points do I need?
At least three points with a response strictly between 0% and 100%.
Can I find EC10 or EC90?
Yes. Data mode returns EC10 and EC90, and the second mode returns any ECx you choose from a known EC50 and slope.
Is EC50 the same as IC50?
EC50 describes the concentration for half of a maximal effect. IC50 is the usual name when the effect is inhibition. The calculation is the same kind of curve fit, but the calculator is built around a response that rises with concentration.