ECG Axis Calculator: QRS Axis From Lead I and aVF

This ECG axis calculator estimates the electrical axis of the heart from the net QRS deflection in lead I and in aVF. Enter the two values, and it returns the axis in degrees, a category of normal, left axis deviation, right axis deviation or extreme axis deviation, and the polarity of each lead.

Sports, Health & Planning Tools Calculators

ECG Axis Calculator

Estimate the electrical axis of the heart from the net QRS in lead I and aVF, and see whether it is normal, left or right deviated.

For learning and checking. Interpretation of an ECG belongs to a clinician.

Starting values: a net QRS of +8 in lead I and -4 in aVF gives an axis of -26.6°, which the calculator places in the normal range of -30° to +90°.

How to use the calculator

  1. Measure the net QRS in lead I, which is the height of the R wave minus the depth of the S wave. A positive result means that the QRS is mainly upright.
  2. Measure the net QRS in aVF in the same way and in the same unit, millimetres or millivolts.
  3. Enter both values and read the axis, the category and the polarity.

At least one of the two values must be non-zero. The calculator works with either positive or negative numbers.

The formula

Axis = atan2(net QRS in aVF, net QRS in lead I), in degrees

On the hexaxial reference system, lead I is at 0° and aVF is at +90°. The atan2 function uses both values, so it places the axis in the correct quadrant. The result is rounded to one decimal place.

The categories used by the calculator

Axis Category
-30° to +90° Normal axis
-30° to -90° Left axis deviation
+90° to +180° Right axis deviation
-90° to -180° Extreme axis deviation

Worked examples

Example 1: the default values

Lead I is +8 and aVF is -4. The axis is atan2(-4, 8) = -26.6°. Lead I is positive and aVF is negative, and the axis falls in the normal range.

Example 2: both leads positive

With +5 in lead I and +5 in aVF, the axis is 45°, in the middle of the normal range.

Example 3: left axis deviation

With +6 in lead I and -8 in aVF, the axis is -53.1°. That lies between -30° and -90°, so the calculator calls it left axis deviation.

Example 4: right axis deviation

With -5 in lead I and +8 in aVF, the axis is 122°, between +90° and +180°, which is right axis deviation.

Example 5: extreme axis deviation

With -6 in lead I and -4 in aVF, the axis is -146.3°. That is in the quadrant from -90° to -180°, which the calculator calls extreme axis deviation.

The quadrant shortcut

The polarity line in the results gives a fast check on the axis. When both leads are positive, the axis lies between 0° and +90°. When lead I is positive and aVF is negative, the axis lies between 0° and -90°, and it is normal only up to -30°. When lead I is negative and aVF is positive, the axis is between +90° and +180°. When both are negative, it is between -90° and -180°. The calculator turns that rough picture into a number.

Common mistakes

  • Using different units for the two leads. Millimetres and millivolts cannot be mixed.
  • Forgetting that the net QRS is R minus S, not just the R wave.
  • Swapping the two leads. Lead I goes in the first box and aVF in the second.
  • Reading a rounded number as exact. A reading near the edge of a range, such as -30°, can easily move across it with a small change in measurement.

Limits

The calculator gives an estimate from two leads. A full ECG interpretation looks at more than the axis, and it belongs to a clinician. The tool is for learning and for checking your own working.

Where the net QRS comes from

Net QRS is a measurement you take from the tracing. In each lead, measure the height of the tallest upward deflection of the QRS complex and the depth of the downward deflection, then subtract the depth from the height. A complex that is mostly upright gives a positive value, and one that is mostly downward gives a negative one. A complex whose upward and downward parts are about equal gives a value near zero, and the axis is then close to perpendicular to that lead.

This is why the two leads work together. Lead I tells you how far the axis points toward the left arm or away from it, and aVF tells you how far it points toward the feet or away from them. Combined, they pin the axis to one quadrant and give a number inside it.

Checking the result against the tracing

Once you have the axis, compare it with what you can see. If both leads look upright but the calculator reports left axis deviation, one of the values has probably been entered with the wrong sign. A quick look at the polarity line in the results catches this at once.

Working on something related? Try the ankle brachial index calculator, maddrey score calculator or crown rump length calculator.

Frequently asked questions

How do I calculate the QRS axis?

Take the arctangent of the net QRS in aVF divided by the net QRS in lead I, using atan2 so that the quadrant is correct. A net +8 in lead I and -4 in aVF gives -26.6 degrees.

What is the net QRS?

It is the R wave height minus the S wave depth in that lead, in the same unit for both leads.

What counts as a normal axis?

The calculator treats -30 to +90 degrees as normal.

What is left axis deviation?

An axis between -30 and -90 degrees, as the calculator defines it.

Can the calculator interpret my ECG?

No. It estimates the axis from two values, and a clinician interprets the full ECG.

Mark Danny

Mark Danny

Mark Danny builds and maintains the free calculators and guides on Area of Irregular Shapes Calculator. Every calculator page explains its formula and shows a worked example, so you can check the working yourself. Spotted a mistake or have a suggestion? Email gulsher.hingoro101@gmail.com.

Articles: 752