Lux to Lumens Calculator: Convert Lux, Lumens and Foot-Candles for Any Area

Lux measures how much light lands on a surface, and lumens measure how much light a source gives out, so you cannot convert between them without knowing the area. Enter a value, the area and a utilisation factor, and this calculator converts lux to lumens or lumens to lux, and also shows foot-candles.

Engineering & Electronics Tools Calculators

Lux to Lumens Calculator

Convert lux to lumens (or lumens to lux) for a given area, with foot-candles and an optional utilisation factor for room lighting.

100 means all the light reaches the surface. Use a lower figure to allow for losses.
1 lux = 1 lumen per square metre. Lux and lumens can only be converted when the area is known.

Starting values: the calculator opens on lux to lumens with 300 lux, an area of 20 m² and a utilisation factor of 100%. It returns 6,000 lumens and about 27.9 foot-candles. These are example values, so enter your own room and target.

The formulas

Lumens needed = Lux × Area ÷ Utilisation factor

Lux delivered = Lumens × Utilisation factor ÷ Area

Foot-candles = Lux ÷ 10.7639

Where the area is in square metres, the utilisation factor is the share of the light that reaches the surface (100% means all of it), and foot-candles are lumens per square foot. If you enter the area in square feet, the calculator converts it first at 0.09290304 square metres per square foot.

The definitions

An architecture reference defines a lux as one lumen falling on one square metre, and a foot-candle as one lumen falling on one square foot. So 1 lux is 1 lumen per square metre, which is the calculator’s note. That page gives the approximation that 10 lux is roughly 1 foot-candle, and the calculator uses the more exact 10.7639, the number of square feet in a square metre.

Worked examples

Example 1: the default

300 lux over 20 m² at 100% needs 300 × 20 = 6,000 lumens. In foot-candles, 300 ÷ 10.7639 = 27.9.

Example 2: allowing for losses

500 lux over 12 m² at a utilisation factor of 60% needs 500 × 12 ÷ 0.60 = 10,000 lumens. The factor raises the lumens you must buy, because only part of the light reaches the work surface.

Example 3: lumens to lux

8,000 lumens in a 20 m² room at a utilisation factor of 80% gives 8,000 × 0.80 ÷ 20 = 320 lux, which is 29.7 foot-candles.

Example 4: an area in square feet

A room of 200 ft² is 200 × 0.09290304 = 18.58 m². For 300 lux at 100%, the lumens needed are 300 × 18.58 = 5,574. At 50% they are 11,148.

Example 5: a dim room

100 lux over 15 m² at 70% needs 100 × 15 ÷ 0.70 = 2,143 lumens.

How much light is enough?

The same architecture reference lists recommended illuminance from the IESNA Lighting Handbook. A few of its values are below, with foot-candles in brackets.

  • Open or private office: 300 to 500 lux (30 to 50)
  • Classroom: 300 to 500 lux (30 to 50)
  • Kitchen or food preparation: 300 to 750 lux (30 to 75)
  • Workshop: 300 to 750 lux (30 to 75)
  • Restroom: 100 to 300 lux (10 to 30)
  • Lounge or breakroom: 100 to 300 lux (10 to 30)
  • Corridor or stairway: 50 to 100 lux (5 to 10)

Pick the level for the space and task, then use the first formula to find the lumens needed. Check your local lighting requirements, which this page does not replace.

Choosing the utilisation factor

The calculator’s hint says that 100 means all the light reaches the surface and that you should use a lower figure to allow for losses. The factor depends on the room, the fittings and the finishes, and I did not find a single standard value, so the calculator leaves the choice with you. If you do not know it, run two or three values and see the range.

What the calculator does not do

  • It assumes the light spreads evenly over the whole area, so it gives an average and not the level at a particular spot.
  • It does not convert lumens to watts. That depends on the efficacy of the lamp, which the calculator does not know.
  • It does not look at beam angle, mounting height or how the light is distributed.
  • It does not apply a maintenance factor for ageing lamps or dirt.
  • It does not choose the lux level for you. Use a recommended value from a standard or reference.

Using the answer to choose lamps

Once you have the lumens needed, compare the total with the lumens printed on the packaging of the lamps you are considering. For a room that needs 6,000 lumens, you could add up the lumens of several fittings, for instance six lamps of 1,000 lumens each, and then check the sum against the target. Using several smaller sources also tends to spread the light more evenly than one bright source.

Checking an existing room

To see how a room measures up, add up the lumens of every lamp, enter them in the lumens to lux mode with the room’s area, and choose a utilisation factor. If the result is well below the recommended level for the space, you need more light or more efficient fittings.

Units to watch

Make sure that a value labelled lux is lumens per square metre, and that a value in foot-candles is lumens per square foot. To go from foot-candles to lux, multiply by 10.7639. For example, 30 foot-candles is 322.9 lux.

Frequently asked questions

How do I convert lux to lumens?

Multiply the lux by the area in square metres, then divide by the utilisation factor as a decimal. 300 lux over 20 m² at 100% is 6,000 lumens.

Why do I need the area?

Lux is lumens per square metre, so the same lumens give fewer lux over a bigger area. Without an area the two cannot be converted.

How many foot-candles is a lux?

Divide lux by 10.7639. 300 lux is about 27.9 foot-candles, and an architecture reference gives the rough rule of 10 lux to 1 foot-candle.

What lux level should a kitchen have?

The IESNA values on one reference list 300 to 750 lux for kitchens and food preparation. Check the requirements for your own project.

Mark Danny

Mark Danny

Mark Danny builds and maintains the free calculators and guides on Area of Irregular Shapes Calculator. Every calculator page explains its formula and shows a worked example, so you can check the working yourself. Spotted a mistake or have a suggestion? Email gulsher.hingoro101@gmail.com.

Articles: 699