Drip Irrigation Line Calculator: Emitters & Flow Rate

A drip line waters at set points along its length. Enter the line length, the emitter spacing, the flow of each emitter and the watering time, and this calculator returns the number of emitters, the total flow and the water delivered.

Lines & Line Sizing Calculators

Drip Irrigation Line Calculator

Number of emitters and total water flow for a drip irrigation line, from line length, emitter spacing, and emitter flow rate.

GPH
hr

Starting values: the calculator opens with a 50 ft line, emitters every 12 in, 1 GPH per emitter and 1 hour of watering. It returns 51 emitters, a flow of 51 GPH and 51 gallons delivered.

The formulas

Emitters = Line length ÷ Spacing, rounded down, + 1

Total flow (GPH) = Emitters × Flow per emitter

Water delivered (gal) = Total flow × Hours

The plus one counts the emitter at the start of the line, so a line with an emitter at each end has one more emitter than the number of gaps. Length and spacing can be in any units, since they are converted together.

Worked examples

Example 1: the default

50 ft ÷ 1 ft = 50, plus 1 = 51 emitters. Flow = 51 × 1 = 51 GPH. In 1 hour, 51 gallons.

Example 2: wider spacing, lower flow

A 100 ft line with emitters every 24 in is 50 gaps and 51 emitters. At 0.5 GPH each, the flow is 25.5 GPH, and 2 hours delivers 51 gallons.

Example 3: a length that does not divide evenly

A 25 ft line with emitters every 15 in is 300 in ÷ 15 in = 20 gaps, so 21 emitters. A 26 ft line is 20.8 gaps, which rounds down to 20, so also 21 emitters, and the last 3 in of the line has no emitter.

Example 4: flow in gallons per minute

51 GPH is 51 ÷ 60 = 0.85 GPM. You need this figure to check your supply and your tubing.

Example 5: working out the watering time

If the plants need 25 gallons from this line, the time is 25 ÷ 51 = 0.49 hours, or about 29 minutes.

Choosing flow and spacing

A state extension fact sheet on drip irrigation gives these guidelines:

  • Point-source emitters for widely spaced plants typically deliver 1/2, 1, 2 or 4 GPH.
  • Line-source tubing has emitters typically spaced 6 to 36 inches apart.
  • Coarse soils need closer spacing and may need more than one line for a wide bed, while on fine soils water from one emitter can spread three feet or more.
  • Tree emitters should be spaced evenly around the trunk near the canopy edge.

Pressure and length

The same fact sheet says drip tubing typically operates at 6 to 12 psi, that emitter flow should vary by no more than 10% between the first and last emitter, and that pressure regulators are recommended on fields with a significant change in elevation. Maximum lateral length depends on the tubing size, spacing and flow, for example up to about 750 ft for 5/8 in tubing with 12 in spacing and 0.22 GPH emitters, and 427 ft with 36 in spacing and 1 GPH emitters. A long line with a high flow may need splitting into sections.

Filtration and run time

Nearly every system needs filtration to stop emitters plugging. The fact sheet also advises that total operation should not exceed 18 hours a day and no zone should run more than 16 hours continuously. As an example, it gives four 2 GPH emitters with a need of 18.8 gallons a day, which is 18.8 ÷ 8 = 2.35, or about 2.4 hours.

What the calculator does not do

  • It assumes every emitter has the same flow at the same pressure. It does not check the pressure drop along the line.
  • It does not decide how much water the plants need.
  • It does not check the maximum length for your tubing.
  • It rounds the emitter count down and then adds one, so the last gap may be shorter than the spacing.

To check flow in a supply pipe, use the pipe line velocity calculator.

Planning a whole bed or zone

Most gardens use several lines on one supply, so the flows add up. The calculator treats a single line, so run it once for each line and add the results.

Example 6: three identical lines

Three 50 ft lines with emitters every 12 in at 1 GPH each have 51 emitters apiece, 153 in all. The total flow is 153 GPH, which is 153 ÷ 60 = 2.55 GPM. Check that your supply can deliver this at the pressure your tubing needs.

Example 7: rows of plants

Five rows 40 ft long with emitters every 18 in: 40 ÷ 1.5 = 26.7, which rounds down to 26, plus 1 gives 27 emitters a row and 135 in total. At 0.5 GPH each the flow is 67.5 GPH, so one hour delivers 67.5 gallons across the five rows.

Example 8: a ring around a tree

Four emitters at 2 GPH is 8 GPH. For a tree that needs 18.8 gallons, the run time is 18.8 ÷ 8 = 2.35 hours. Here you enter the emitter count directly in your head, because the calculator’s count comes from a straight line.

Matching zones to your supply

If the total flow of all lines is more than the supply can give, split the lines into zones and water them one after another. The run time for each zone follows from the same formula, so the total watering session is the sum of the zone times. Keep each zone within the daily limits in the extension advice above.

Frequently asked questions

How many emitters do I need on a drip line?

Divide the line length by the spacing, round down, and add one. A 50 ft line with emitters every 12 in has 51 emitters.

How do I find the total water flow?

Multiply the number of emitters by the flow of each. 51 emitters at 1 GPH is 51 GPH, or 0.85 GPM.

How far apart should emitters be?

A state extension fact sheet says line-source emitters are typically spaced 6 to 36 inches apart, closer on coarse soils.

How long should I run the line?

Divide the gallons the plants need by the total flow in GPH. 25 gallons at 51 GPH is about 29 minutes.

Mark Danny

Mark Danny

Mark Danny builds and maintains the free calculators and guides on Area of Irregular Shapes Calculator. Every calculator page explains its formula and shows a worked example, so you can check the working yourself. Spotted a mistake or have a suggestion? Email gulsher.hingoro101@gmail.com.

Articles: 739